+86 18068001229 Amorphous Alloy Transformer Uye Silicon Steel Transformer
Unoziva here musiyano uripo pakati pe Amorphous Alloy Transformers uye matransformer esimbi esilicon akajairika? Semugadziri wetransformer ane ruzivo rwemakore anopfuura gumi nemashanu, JZP inotsanangura musiyano uripo pakati pemhando mbiri idzi dzetransformers. Haisi kungova musiyano wezvinhu chete; ihondo yetekinoroji pakati pekushandisa simba zvakanaka, mutengo, uye mafambiro emangwana.
Alloy yeAmorphous Vs. Transformer Yenguva Dzose
Transformer yeSimbi yeSilicon Yakajairika
Matransformer akajairika ane macore akagadzirwa nesimbi yesilicon yakaputirwa inotonhora, inotarisa zviyo, ine maatomu akarongwa muchimiro chakachena, chakajairika.
Kurongeka uku kwakarongeka kunoita kuti simba remagineti ridzikire zvakanyanya kana rikaitwa nemagineti nenzira inotenderera, zvichikonzera kushanda kwakanaka. Zvisinei, achiri makristaro, uye magineti anoshandisa simba, zvichikonzera "kurasikirwa nehysteresis." Uyezve, machira esimbi esilicon ane ukobvu hwakati, uye simba remagineti rinochinjana rinokonzeresa "eddy currents" mukati mawo, zvichikonzera "kurasikirwa ne eddy current," pamwe chete kunozivikanwa se "kurasikirwa nesimbi."
Amorphous Alloy Transformer
Pakati pechinhu chinoshandura aloyi chisina chimiro chakagadzirwa neribhoni isina chimiro, inozivikanwawo se "girazi resimbi." Kurongeka kwayo kwemaatomu hakuna kurongeka uye hakuna kurongeka. Chimiro ichi chinoumbwa nekutonhodza nekukurumidza kunyunguduka kwekupisa kwakanyanya pamwero wemamiriyoni emadhigirii pasekondi, maitiro akasiyana. Kusagadzikana kweatomu uku kwenguva refu kunoderedza zvakanyanya kurasikirwa kwehysteresis; ukobvu hwayo hwakatetepa zvakanyanya uye resistivity yakakwirira kunoderedza kurasikirwa kwe eddy current.
Kuenzanisa Kwekushanda
| Kuenzanisa | Amorphous Alloy Transformer
| Transformer yeSimbi yeSilicon Yakajairika
| Kuongorora uye Dudziro
|
| Kurasikirwa Kukuru
| Zvakanyanya Kuderera
| Yakakwirira
| Kurasikirwa pasina mutoro, paavhareji, kwakaderera ne60%-80% pane maS13/S14 silicon steel transformers akafanana.
|
| Hapana mutoro wezvino
| Diki
| Hombe
| Kushanda kwemagetsi kusina mutoro kunogona kuderedzwa neinenge 40%-80%, zvinoreva kuti simba remagetsi harina simba rakawanda uye kurasikirwa kwemagetsi epasi.
|
| Chikamu Chekushandisa Simba Zvakanaka
| Yakakwira Zvikuru
| Yakakwirira
| Matransformer asina chimiro anosangana zviri nyore nedanho renyika reClass I rekushandisa simba zvakanaka, zvichiratidza kushanda zvakanaka kwesimba zvakanyanya kana tichienzanisa nematransformer esimbi yesilicon (kazhinji eClass II kana Class III).
|
| Mutengo wekugadzira
| Yakakwirira
| Zvakaderera Zvishoma
| Mutsetse wesimbi usina chimiro unodhura, wakaoma, uye hauchabatiki, uye maitiro ekuchekerera nekunamira akaomarara, zvichiita kuti mitengo yekugadzira ikwire ne20%-35% kupfuura simbi yesilicon ine simba rakaenzana. Uku ndiko kuipa kwayo kukuru.
|
| Simba reMichina
| Zvakaderera
| Yakakwirira | Mutsetse wesimbi usina chimiro wakaoma uye haupindiki, hauna simba rekudzivirira kuvhunduka kana kudedera. Kungwarira kwakakosha kunofanirwa kutorwa panguva yekufambisa, kuisa, uye kuvhunduka kwemhepo kwenguva pfupi. Sheet resimbi resilicon rakasimba zvikuru uye rinodzivirira kuvhunduka zviri nani.
|
| Kushanda kwesimba remagineti
| Yakaderera (1.3-1.5T)
| Yakakwira (1.6-1.8T)
| Kuwanda kwemagineti eflux e amorphous alloys kwakaderera, zvinoreva kuti nzvimbo yakakura yepakati inodiwa nesimba rimwe chete, izvo zvinogona kukonzera kuwedzera kudiki kwehuwandu nehuremu hwe transformer.
|
| Ruzha rwekushanda
| Yakakwirira Zvishoma
| Zvakaderera
| Mhedzisiro yemagnetostrictive (kuchinja kudiki muhukuru hwezvinhu kana zvaiswa magineti) yeamorphous alloys inoonekwa zvakanyanya kupfuura iyo yesimbi yesilicon, zvichikonzera hum yakakwira zvishoma (inenge 2-5 dB yakakwira) panguva yekushanda. Kubata kwakakosha kunogona kudiwa munzvimbo dzinonzwa ruzha.
|
| Kushanda Kwezvakatipoteredza
| Zvakanakisa
| Kugona | Kurasikirwa kwakanyanya pasina mutoro kunoreva kuchengetedza simba zvakanyanya muhupenyu hwese (makore 20-30), zvakaenzana nekuderedza kuburitswa kwecarbon nematani akati wandei kana kunyange makumi ematani. |
Matransformer esimbi yesilicon akajairika: Mari yekutanga yakaderera, asi mitengo yemagetsi ekushanda yakakwira. Kurasikirwa kwavo pasina mutoro kunoitika maawa makumi maviri nemana pazuva, zvichishandisa magetsi asingaperi chero bedzi transformer yakabatana negrid.
Matransformer emhando yepamusoro: Mari yekutanga yakawanda, asi mitengo yemagetsi ekushanda yakaderera zvikuru. Kuchengetedza kwavo simba kunogona kunge kusingakoshi pazuva rimwe chete, asi muhupenyu hwavo hwese (makore 20-30), kuchengetedza kwavo kunogona kunge kunoshamisa.
Kune mabhizinesi ane huwandu hwakawanda hwe Transformer yekugoveras uye zvinhu zvinorema zvishoma (zvakadai semakambani emagetsi, nzvimbo dzedata, uye nzvimbo huru dzekutengeserana), zvakanakira zvehupfumi zvematransformer asina chimiro zvinokwezva zvikuru.












