+86 18068001229 Zvikanganiso zveTransformer Zvakajairika Zvakagadziriswa
Kuongororwa Kwezvikanganiso zveTransformer uye Nzira dzeKugadzirisa Matambudziko
Matransformer, semidziyo mikuru mumasisitimu emagetsi, inoita mabasa akakosha anosanganisira kushandura voltage, kutonga kwemagetsi, uye kupatsanurwa kwemagetsi. Kushanda kwavo kwakasimba kwakakosha pakuona kuchengetedzeka uye kushanda zvakanaka kwemanetwork emagetsi. Zvikamu zvinotevera zvinopa ongororo yakadzama yekutarisira mashandiro etransformer, nzira dzakajairika dzekuona kukanganisa, uye maitiro ekugadzirisa matambudziko.
Maitiro Ekugadzirira uye Kuongorora Transformer Commissioning
Usati watanga kushandisa transformer, ongororo yakazara inofanira kuitwa kuti ionekwe kuti yakagadzirira kushanda zvakanaka:
Kuongororwa kweChisungo neKubatanidza: Ita ongororo yakakwana yezvisungo zvese zviri mukati nekunze kwetransformer, kunyanya panzvimbo dzakakosha dzekubatanidza dzakadai sema terminal emagetsi nemabhazi. Iva nechokwadi chekuti torque yashandiswa zvakanaka panguva yekusunga kudzivirira kukuvara kweshinda, uku uchidzivirira kubata kunokonzerwa nekusawirirana kwezvinhu pakati pemabhaudhi nenzungu.
Kusimbiswa Kwekuiswa Kwezvikamu: Edza kudzoserwa kwakakodzera kwezvikamu zvese zvakabviswa panguva yekufambisa kana kuisa, tarisa madhiraivha ekutonhodza emukati kuti aone kana pasina marara, uye simbisa kusavapo kwezvishandiso zvasara mukati me transformer enclosure.
Kuongororwa kweMudziyo weKudzora Tembiricha: Iva nechokwadi chekuti tambo dzekutonga dzevanodzora tembiricha nezviratidzo zvinodzoserwa kure nepamusoro pemakoira nezvikamu zvipenyu. Chengetedza zvakare sezvinodiwa kudzivirira kukanganiswa.
Sisitimu Yekutonhodzauye Kuongorora Midziyo Yekubatsira: Simbisa mashandiro akanaka emafeni ekutonhodza, michina yekudzora tembiricha, uye masisitimu ekuwedzera. Simbisa zvakananga divi rekutenderera kwefeni kuti uve nechokwadi chekuti mhepo yakananga kumusoro kubva pasi pemawindings etransformer.
Miedzo yeTransformer Pre-Commissioning
Kuti zvionekwe kuti zvinotevedzera zvinodiwa pakugadzira, bvunzo dzinotevera dzinofanira kuitwa tisati tatanga kushandisa transformer:
Kuyerwa kweDC Resistance: Ita zviyero zvekudzivirira kutenderedza munzvimbo dzese dzepombi kuti uone kuti zvinoenderana nezvinodiwa pakugadzira.
Kuyerwa kweVoltage Ratio: Simbisa kururama kwekushandurwa kwemagetsiratios uye kusimbisa kururama kwemazita evector group kuburikidza nekuongorora polarity uye phase sequence.
Bvunzo reKudzivirira Kudzivirira: Ita bvunzo dze dielectric pakati pepakati nepakati pezvimiro zvekusunga kuti uone kuvimbika kwekudzivirira.
Muedzo weKudzivirira Kudzivirira Kuvharwa Kwemhepo: Yera kudzivirira kuvharwa kwemhepo kuti uone kutevedzera kuchengetedzeka kwemagetsi.
Kuedza Kutsungirira Kwemagetsi: Kune ma transformer akagadziriswa mumunda adzoka kushanda, kuyedzwa kwemagetsi ekudzivirira magetsi e dielectric kunofanira kuitwa pa80% yehuwandu hwemagetsi ekutanga ekuedzwa kwefekitori, zvichienderana nezvinodiwa neIEC 60076-3 Clause 10.
Kungwarira pakushanda zvakachengeteka kwematransformer
Kuongorora Sisitimu Yekudzika: Ita ongororo yakasimba yesisitimu yekudzika mushure mekuiswa kuti uone kushanda kwayo kwakachengeteka uye kwakavimbika.
Zvipingamupinyi zveKuchengetedza: Matransformer asina dziviriro yekuvhara anofanira kunge aine zvipingamupinyi zvekudzivirira kusangana zvakananga nezvinhu zvipenyu uye kuderedza njodzi dzekurohwa nemagetsi.
Kushanda kweVashandi Vane Chitupa: Kuisa, kupa basa, uye kugadzirisa matransformer kunofanirwa kuitwa chete nenyanzvi dzakanyoreswa kuti ive nechokwadi chekuti mitemo yekushanda inotevedzwa uye mitemo yekuchengetedza.
Matanho Ekudzivirira Pakushandisa Transformer
Kushanda kweSisitimu Yekudzora Kupisa: Usati waisa simba, gadzirisa uye edza chinodzora tembiricha kana chinoratidza tembiricha kuti uone kushanda kwayo kwakakodzera.
Maitiro Ekusimbisa: Vhara macircuit breakers netransformer pasina mutoro. Shandisa instantly overcurrent protection relay panguva yekusimbisa simba kuderedza mhedzisiro ye inrush current.
Kuwedzera zvishoma nezvishoma mutoro: Mushure mekuiswa mukushanda, mutoro unofanira kuwedzerwa zvishoma nezvishoma uye kutariswa kuti uone kana paine ruzha rusina kujairika kana kudedera kudzivirira kuwedzera kamwe kamwe mutoro.
Nzira Yokuderedza Hunyoro: Kune ma transformer asina simba akavharirwa nehunyoro hwemhepo >80% RH.
Zvikanganiso zveTransformer Zvakajairika uye Zviito Zvekugadzirisa
Kukanganisa kupisa zvakanyanya: Izvi zvinosanganisira kupisa kwakanyanya munzvimbo imwe chete uye kukwira kwakanyanya kwekupisa. Tarisa mutoro, simba remagetsi, uye mamiriro ekupisa.
Zvikanganiso pakubuda kwemvura: Zvinogona kuonekwa sekubvisa mvura zvishoma, kubuda kwemvura muarc, kana kubuda kwemvura muspark; zvinowanzobatanidzwa nematambudziko ekudzivirira kupisa.
Dambudziko rekudzivirira: Zvakadai sekuputsika kwekudzivirira kana kudzikira kwekushanda kwekudzivirira; zvinhu zvinodzivirira zvakakuvara zvinofanirwa kuongororwa nekukasika uye kutsiviwa.
Zvimwe zvikanganiso: Kusanganisira ruzha rusina kujairika, kutadza kushanda zvakanaka kwedziviriro, kudonha kwemafuta, nezvimwewo.
Nzira dzeKuziva Mhosva:
Kuongorora zvinoonekwa: Tarisa kuti mafuta ari kuyerera sei, ruvara rwemafuta rwunoshanduka sei, uye kuti chitarisiko chekunze hachina kumira zvakanaka here (semuenzaniso, mafuta ari kubuda, kana kuti ruvara rwachinja).
Kutarisa nzeve: Teerera ruzha rusina kujairika panguva yekushanda (semuenzaniso, ruzha rusina kuenzana, ruzha rwekukwenya, kana ruzha rwekushinyira).
Kuyera kwemagetsi: Pima kuramba kweDC kwezvikamu zvitatu uye kuramba kudziya kwemhepo kuti uone kana kukosha kuri mukati mehuwandu hwakajairika.
Kugadziriswa Kwekukanganisa Kwekushanda Kwekuputira
Kudzikira kwekushanda kwekudzivirira kupisa (insulation performance) idambudziko rinowanzoitika mumatransformer, kunyanya munzvimbo dzine hunyoro. Bvunzo yekudzivirira kupisa inofanira kuitwa mumamiriro ezvinhu akakodzera, nematanho anotevera:
HV kuenda kuLV uye kugayiwa: ≥ 300 M Ω (10kV), ≥ 1000 M Ω (35kV).
HV kusvika pasi: ≥100 MΩ.
Kuti uwane zvinhu zvepakati/zvishongedzo zvepasi, tarisa magwaro emugadziri.
Kana transformer ikawana hunyoro kana kunyorova (semuenzaniso, madonhwe anooneka pamusoro pe epoxy resin kana zvikamu zvepakati), kuoma nekukurumidza kunodiwa kuti insulation irambe yakasimba, zvisinei nekuti insulation yayo iri kuramba kushanda zvakanaka sei.
Transformer Abnormal Noise Mitigation Protocol
Kushanda kwakajairika kwetransformer kunoburitsa ruzha runochinja-chinja zvichienderana nemutoro. Kana paine ruzha rusina kujairika, ongororo yakawanda inodiwa:
Kusunungura tsinga dzemukati: Kunoita ruzha runorira kana kuti runotenderera nekuda kwekunge simbi dzisina kuvharwa kana kuti torque isina kukwana.
Mhepo isina kuzununguka: Inogadzira ruzha rwekubuda kwemhepo kubva pakuungana kwemagetsi pakati pemhepo netangi.
Zvikanganiso zvekubatana kwemagetsi: Zvinokonzera kurira kana kurira kwemagetsi kubva mukutenderera kwematap changer kana ma busbar joints.
Kuburitsa mutobvu/kumonereka: Kunoburitsa ma arc anonzwika kubva mukuputsika kwe insulation munzvimbo dzine voltage yakawanda.
Mabushings ane tsvina: Anokonzera kubuda kwekorona kunotyisa nekuda kwekuunganidzwa kwemafuta pamusoro/tunhu.
Kugadzirisa Matambudziko Ekutonga Tembiricha
Kutadza Kubatidza: Tarisa simba, mafiyuzi, kubatana kweterminal, uye mamiriro eswitch.
Hapana Kuratidzwa Kwekupisa: Tarisa kubatana kwesensa uye kuramba kwayo.
Kutsauka pakupisa: Tarisa kuiswa kwemasensa uye masosi ekupindira.
Kukundikana Kutaurirana: Tarisa mutsetse wekutaurirana uye taura nerutsigiro rwehunyanzvi rwemutengesi.
Mhinduro dzeKuderedza Kusawirirana kweMagetsi Emagetsi Emadanho Matatu
Kusawirirana kwemagetsi echikamu chechitatu kunowanzo kukonzerwa nekutadza kwepasi kana kusawirirana kwemutoro. Mhinduro dzinosanganisira:
Kuisa Nzvimbo Dzakawanda Dzepasi Kuti Kudzikise Kurasikirwa Nemutsetse Wakaderera: Isa nzvimbo dzakawanda dzepasi mumagetsi mashoma ekugovera ma network kuti uderedze kurasikirwa kwemagetsi emutsetse wakaderera nekugadzirisa nzira dzekudzoka kwemagetsi uye kuderedza impedance.
Transformer yeChikamu Chimwe Chete Kushandiswa: Shandisa ma transformer echikamu chimwe chete munzvimbo dzine mitoro yakawanda yechikamu chimwe chete (semuenzaniso, nzvimbo dzekugara) kuti uparadzanise mafungu asina kuenzana uye kudzivirira kupindirana kwe harmonic.
Kutarisa Mutoro & Kuenzanisa: Ita zviyero zvemutoro nguva nenguva uchishandisa mita dzekubatanidza kuti uone kutsauka kwemagetsi pakati pezvikamu.
Kuchinja Ruvara rweOiri & Kurapa Kudzora Kudonha Kwemvura
Kusviba Kwemafuta: Kusviba kwemafuta (semuenzaniso, amber inoshanduka kuita brown/dema) kunoratidza kunyudzwa kwehunyoro uye kuora kweokisijeni, zvichikonzera kudzikira kwesimba re dielectric uye kuwedzera kweacidity. Tsiva mafuta akaora nekukurumidza kudzivirira kukwegura nekukurumidza uye kutadza kwemidziyo.
Kubuda Kwemafuta: Sarudza kana uchifanira kuramba uchishanda uye kuronga kugadzirisa zvichienderana nemamiriro ekubuda kwemafuta, kana kuti dzima wobva wadzorera mafuta.
Mukupedzisa, Kushanda kwakasimba kwematransformer ndiyo musimboti wekuvimbika kwesimba remagetsi. Kuburikidza nekuongorora kwakanyatsonaka, kuongororwa/kugadziriswa kwezvikanganiso nekukurumidza, uye kugadziriswa nekukurumidza, hupenyu hwekushanda kwematransformer hunogona kuwedzerwa zvinobudirira, mwero wekukundikana unoderedzwa, uye kuchengetedzeka/kushanda zvakanaka kwemasystem emagetsi kunovimbiswa.