+86 18068001229 Mukati meJZP's Three-Phase Pad-Mounted Transformer: Kunyura Kwakadzika muSmart Grid Innovation

Mumamiriro ezvinhu ari kuchinja ehunyanzvi hwemagetsi, ma transformer eJZP ane ma pad-mounted matatu (PMTs) ave mhinduro inochinja-chinja kuti zvinhu zvishande zvakanaka. Kugoverwa KwesimbaKubatanidza dhizaini diki neinjiniya yemazuva ano, aya "ma "smart energy hubs" anotsanangura patsva kuvimbika uye kuchengetedzeka. Ngationgororei hunhu hwakaoma hweJZP's PMTs toona zvishamiso zvetekinoroji zvinosimbisa zvivakwa zvemazuva ano.
1. Magadzirirwo eModular: Sero reSimba reUngwaru
MaPMT eJZP anoshandisa dhizaini ye "SmartCube" inochinja-chinja iyo inobatanidza masisitimu matatu akakosha muchikamu chimwe chete, chinodzivirira mamiriro ekunze:
Kamuri reHigh-Voltage: Maswichi ekubvisa mutoro akavharirwa ne vacuum ane SF6 gas insulation
Transformer Core: Advanced amorphous alloy core inoderedza kurasikirwa kwesimba
Kugoverwa kweVoltage Yakaderera: Vatongi velogic vanogona kurongwa vane kubatana kweIoT
Dhizaini iyi inoderedza nguva yekuisa ne60% kana tichienzanisa nezviteshi zvechinyakare uye inotora nzvimbo shoma ne40%.
2. Sisitimu Yemagetsi Akakwira: Uinjiniya Wekuchengetedza Kutanga
2.1 Sisitimu yekudzivirira yehybrid
Vacuum Interrupter: Yakayerwa 63kA short-circuit current ine mashandiro emakanika zviuru gumi
Mafusi Anonzwa Zvinhu Zviviri: Kutarisa Tembiricha + Kutarisa Kushandiswa Kwemagetsi Kwekudzivirira Kudzivirira
Kuvharira Michina: Kunodzivirira simba risingatarisirwi panguva yekugadzirisa
2.2 Mabhachi Akangwara
Polymer Insulators: Inotsungirira simba remunda re100kV/m
RFID Tagging: Inobvumira kutarisa mamiriro asingakuvadzi
Kuzvichenesa: Kunoderedza kudzimwa kwemvura nekuda kwekusvibiswa ne75%
3. Musimboti weTransformer: Magnetic Mastery
3.1 Tekinoroji yeAmorphous Alloy
| Paramita | Tsanangudzo yeJZP | Standard yeIndasitiri |
| Kurasikirwa Kwepakati (W/kg) | ≤0.12 @50Hz | 0.35 |
| Kuwanda kweMagineti | 1.45T | 1.5T |
| Ruzha Rweruzha | ≤45dB(A) | ≤55dB(A) |
Dhizaini ye triple-limb stacked core inoderedza kurasikirwa kwe eddy current ne40% kuburikidza nenzira dzakagadziriswa dze flux
3.2 Matrix Inotonhodza Inoshanda
Nyaya Yekuchinja-Phase (PCM) Layers: Inonwisa 300kJ/m³ yekupisa
Mafin Anokurudzira Vortex: Wedzera kutenderera kwechisikigo ne250%
Maitiro Ekutonhodza eHybrid: Chinja otomatiki pakati pe convection/radiation zvichibva pamutoro
4. Sisitimu yeVoltage Yakaderera: Ungwaru hweGrid-Interactive
Kugadzirisa Simba Rinochinja
Adaptive VAR Compensation: Inochengetedza PF >0.98 mumamiriro ese ekuremerwa
Kuderedza Harmonic: Sefa inoshanda ye4th-order inodzima maharmonics anosvika makumi maviri nemashanu
Kudzivirira Kudzima Kwemagetsi: Kutamisirwa kuUPS pasina musono mu
5. Pakeji Yokutsungirira Kwezvakatipoteredza
5.1 Dziviriro Yepamusoro Yemauto
Chiyero cheIP68/IP69K: Inorarama mumvura inosvika mamita maviri kwemaminitsi makumi matatu
Kuramba Kupisa Munyu: Kupfuura bvunzo yeASTM B117 yemaawa 1000
Kudzivirira kweEMI: 5.2 Zvinhu Zvisingakuvadzi Chimiro
Mvura yeDielectric inoora: 100% ester inogadzirwa nezvirimwa
Aruminiyamu Inodzokororwa: 98% yezvinhu zvinodzokororwa
Dhizaini yeZero-Oil Leakage: Inoshandisa nitrogen yakamanikidzwa
6. Zvinhu zvekubatanidza Smart Grid
Distributed Energy Resource (DER) Interface: Inotsigira kubatanidzwa kwe solar PV/Storage
Kudzoreredzwa kweDynamic Voltage (DVR): Kuchengetedza kugadzikana kwevoltage ye±1%
Demand Response Gateway: Inobatanidzwa mumisika yemabasa ekuwedzera
Nhau dzeKubudirira kweKushandisa
Madhiri eUrban Microgrids: Kupa simba dzimba dzinopfuura 15,000 muGuta Rinogara Richigara muDubai
Mhinduro dzeData Center: 99.999% nguva yekushandisa yezvivakwa zveAWS muSingapore
Kugadziriswa kweMagetsi muNjanji: 25kV AC/DC kushandurwa kwezvitima zvinomhanya 300km/h
Bata JZP Nhasi
Gadzira Remangwana Renyu reSimba neIntelligent Transformer Solutions
Rutsigiro rwehunyanzvi: +86 16655239333
Zvese zvinodiwa zvehunyanzvi zvinoenderana neIEC 60076-11 uye UL 1561.
Kusimudzira grid remangwana nhasi - JZP Power Solutions












