Sisitimu ye "Five Preventions" muzviteshi zvemagetsi inzira yakakosha yekuchengetedza yakagadzirirwa kudzivirira zvikanganiso zvekushanda uye kuona kuti michina yemagetsi ine simba rakawanda inoshanda zvakachengeteka uye zvakavimbika. Sezvo magrid emagetsi achiramba achioma, masisitimu aya anoita basa guru mukuderedza njodzi dzakadai setsaona dzemagetsi, kukuvara kwemidziyo, uye kudzimwa kwemagetsi. Chinyorwa chino chinoongorora tsananguro, zvikamu, misimboti yekushanda, uye mashandisirwo anoshanda eFive Preventions muzviteshi zvemagetsi zvemazuva ano.

 

  1. Tsanangudzo yeZvidziviriro Zvishanu

 

Dziviriro shanu dzinoreva dziviriro shanu dzakakosha dzakabatanidzwa mumidziyo ye substation kubvisa zvikanganiso zvevanhu panguva yekushanda. Izvi zvinosanganisira:

 

Kudzivirira Kusashandiswa Zvisina Kunaka kweMacircuit Breakers: Kuve nechokwadi chekuti macircuit breakers haana kuvhurwa kana kuvharwa zvisiri izvo, izvo zvinogona kukanganisa kufamba kwemagetsi kana kukuvadza michina.

 

Kudzivirira Mashandiro eSwitch yeKuzviparadzanisa neMutoro: Kurambidza kuvhurwa kana kuvharwa kwemaswitch ekuzviparadzanisa pavanenge vari pasi pemutoro, mamiriro ezvinhu anogona kukonzera kuvharika kwesimbi kana kutadza kwemidziyo.

 

Kudzivirira Kuiswa kweWaya Dzinodzika Pasi: Kuedza kubatanidza waya dzinodzika pasi kana maswichi kumasekete ari mupenyu, izvo zvinogona kuisa njodzi yekupfupika kwakanyanya.

 

Kudzivirira Kuvhara Macircuit Breaker Newaya Dzinodzika: Kuve nechokwadi chekuti macircuit breaker haagone kuvharwa kana waya dzinodzika kana maswichi achiri akabatanidzwa, kudzivirira kubuda kwezvinhu zvisina kunaka.

 

Kudzivirira Kupinda Munzvimbo Dzisina Mvumo: Kurambidza kupinda munzvimbo dzemagetsi kunze kwekunge mitemo yese yekuchengetedza yasimbiswa.

 

Matanho aya anosimbiswa kuburikidza nekukiya kwemakanika, kudzora kwemagetsi, uye mashandiro ekushanda kubvisa kusanzwisisika mumamiriro ezvinhu ane njodzi huru.

 

  1. Nheyo dzeKushanda dzeZvidziviriro Zvishanu​

 

Sisitimu iyi inoshanda kuburikidza nemusanganiswa wekuongorora kwepamberi pekushanda kwakavakirwa pakufananidzira uye kusimbiswa kwelogic panguva chaiyo:

 

Kushandiswa Kwekufananidzira: Pamberi pekuvhiyiwa kwemuviri, mainjiniya vanotevedzera kutevedzana kwekombuta ye "Five Prevention Host". Sisitimu iyi inotarisa matanho ainotarisirwa nemirairo yayo yelogic yakarongwa kare uye mamiriro emuchina wazvino (semuenzaniso, nzvimbo dzecircuit breaker, mamiriro ewaya yekumisa).

 

Kukiya Kwepfungwa: Kana basa rikatyora mitemo yekuchengetedza (semuenzaniso, kuedza kuvhura chinovhara dunhu chiripo), sisitimu inovhara basa racho uye inozivisa mushandi. Mirairo inoshanda chete ndiyo inotumirwa kumakiyi chaiwo (semuenzaniso, makiyi ane makodhi kana makiyi ekubatanidza makiyi) kuti ibvumidze kuitwa.

 

Kutarisa Munguva Chaiyo: MaSensor uye maAssistant Contacts paMidziyo Anopa Data Status kuSisitimu, zvichiita kuti pave nekuenderana pakati peControl interface nemamiriro chaiwo. Masisitimu epamusoro anoshandisa Dual-Contact Signals uye Automatic Alignment Alignment algorithms kuderedza manyepo enhema.

 

  1. Matambudziko neMhinduro

 

Kunyange zvazvo Zvidziviriro Zvishanu zvichikosha, matambudziko achiripo:

 

Kururama kweChiratidzo: Kusawirirana kwakashata kana zviratidzo zvenguva pfupi zvinogona kukanganisa sisitimu. Semuenzaniso, nzvimbo isina kutaurwa zvakanaka yecircuit breaker inogona kunzvenga kuongororwa kwekuchengetedza.

 

Mhinduro: Isa ma sensor ekubata maviri uye masaini enzvimbo chaiyo. Kana paine kusawirirana, sisitimu inotanga maalarm uye inovhara mashandiro kusvika yasimbiswa nemaoko.

 

Kuomarara muKuvandudza: Kugadzirisa zviteshi zvekare zvemagetsi nemaitiro emazuva ano eFive Prevention kunoda kugadzira patsva ma-interlocks nemitemo yelogic.

 

Mhinduro: Magadzirirwo emodular uye Nzvimbo Yakagadziriswa Yakagadzirwa Nekares (semuenzaniso, zviteshi zvidiki zve35kV) zvinobatanidza zvinhu zvishanu zvekudzivirira panguva yekuvaka, zvichiita kuti zvigadziriso zvive nyore.

 

  1. Mashandisirwo Anoshanda​

 

Chidzidzo Chekutanga: MuXinjiang, China, sisitimu ye "Five Prevention" pa110kV Luokou Substation yakagadziriswa zvakanyanya muna 2023. Matambudziko anopfuura 1,891 akagadziriswa, kusanganisira makiyi ekare uye zvikanganiso zvelogic, zvichiita kuti pave nekuchengetedzeka kwe100% pakushanda munguva yechando.

 

Chidzidzo Chechipiri: Zviteshi zvemagetsi zvakagadzirwa kare munzvimbo dzemaguta (semuenzaniso, dzimba dzekugara) zvinosanganisira zvinhu zvishanu zvekudzivirira zvakaita seSF6 load-break switches uye masisitimu ekuchengetedza kupisa kudzivirira kupisa zvakanyanya uye kupinda pasina mvumo.

 

  1. Mafambiro Emangwana​

 

Kubatanidzwa kweAI: Maalgorithms epamusoro, akadai sekugadzirisa koloni yemasvosve, ari kuyedzwa kuti aite kuti mitemo ishande zvakanaka uye kuderedza kupindira kwevanhu mukugadzira maprotocol mashanu ekudzivirira.

 

Kutarisa Kunogoneswa neIoT: Masensa akangwara uye mapuratifomu akavakirwa mugore zvichaita kuti data rigovanwe panguva chaiyo pakati penzvimbo dzakasiyana, zvichivandudza kugadziriswa kwekufanotaura uye kuonekwa kwezvisina kujairika.

 

Mhedziso​

 

Sisitimu yeFive Preventions ndiyo musimboti wekuchengetedzeka kwezviteshi zvemagetsi, ichisanganisa mashandiro emakanika nepfungwa dzakangwara kudzivirira zvikanganiso zvinotyisa. Sezvo magridi achichinja kuita magridi akangwara uye kubatanidzwa kwesimba rinodzokororwa, kufambira mberi muAI nekugadzira modular kuchawedzera kusimbisa basa rayo mukuchengetedza kugadzikana kwegridi. Kune makambani emagetsi, kuisa mari muzvivakwa zvakasimba zveFive Prevention hakusi kungodiwa kwemutemo chete asi chinhu chakakosha kuchengetedza zvivakwa uye kuchengetedzeka kwevanhu.