ATransformer yemwenje yemigodhiimhando yakakosha yetransformer yakagadzirirwa kupa simba kumarambi mumigodhi (kusanganisira migodhi yemarasha neisiri yemarasha). Basa rayo guru nderekupayakachengeteka, yakavimbika, uye yakagadzikanavoltage yakaderera yekushandisa michina yemwenje yepasi pevhu.

Hunhu Hukuru uye Chinangwa Chekugadzira:

 

Kuchinja kweVoltage:Kazhinji inoshandura voltage yakakwira yegrid yemagetsi yemugodhi (semuenzaniso, 660V, 1140V) kuitaChengetedzo Yekuwedzera-Yakaderera Voltage (SELV)zvinodiwa nehurongwa hwemwenje, kazhinji127V. . Huremu hwemagetsi uhwu hunoonekwa sehwakachengeteka munzvimbo dzine hunyoro, dzinofambisa magetsi, zvichideredza zvakanyanya njodzi yekuvhunduka kwemagetsi.

 

Kuzviparadzanisa Nevamwe Vakachengeteka:ITransformer yekuzviparadzanisa. Kutenderedza kwayo kwechipiri (divi rekubuda) kwakaparadzaniswa nemagetsi kubva panyika nepakutenderedza kwekutanga (divi rekupinza). Izvi zvinoreva kuti kunyangwe mucheri wemigodhi akabata mutsetse mumwe chete we127V output pamwe nepasi panguva imwe chete, denderedzwa rakavharwa harizogadzirwe, nokudaro zvichidzivirira kuvhunduka kwemagetsi.

 

Mutoro Wakatsaurirwa:Chinangwa chayo chekugadzira ndechekupa mitoro yemwenje (semuenzaniso, marambi eincandescent, marambi e LED). Hunhu hwemutoro hwakagadzikana, uye kugona kwacho kunowanzova kudiki (kubva pa kVA shoma kusvika pamakumi e kVA).

 

Dziviriro Yekutanga:Kunyangwe iine zvimwe zvinhu zvekudzivirira mumigodhi (sekudzivirira hunyoro, kudzivirira kuvhunduka), chinangwa chayo chikuru ndechekupa simba rakachengeteka, kwete hazvo kubata huwandu hwakawanda hwemagasi anoputika.

 

Muchidimbu, Mining Lighting Transformer ndiyo "moyo wakachengeteka" wedunhu remwenje remugodhi; basa rayo guru "kudzivirira kuvhunduka."

Chii chinonzi Transformer yeMigodhi Isingaputike?

AnTransformer yeMigodhi Isingakuvadzi KuputikaIpfungwa yakakura inotaura nezvematransformer ese ekuchera akagadzirirwa kudzivirira kupisa kwemusanganiswa wegasi rinoputika wakapoteredza uye anogona kushandiswa munzvimbo dzine njodzi dzinoputika. Haisi sosi yemagetsi chete asi chikamu chikuru chesimba rese repasi pevhu.

Hunhu Hukuru uye Chinangwa Chekugadzira:

 

Kuvakwa Kusingakuvadzi Kuputika:Ichi ndicho chinhu chikuru chayo. Inoshandisa nzvimbo dzakasarudzika dzisingaputike ("Mhando dzeDziviriro"), semuenzaniso:

 

Nzvimbo Inodzivirira Murazvo ('Ex d'):Nzvimbo iyi inogona kutsungirira kuputika kwemukati uye kudzivirira murazvo wemukati kuti usapararire mumhepo yekunze, nokudaro isingabatidzi gasi rakakomberedza.

 

Kuchengetedzwa Kwakawedzerwa ('Ex e'):Mamwe matanho anoshandiswa kune transformer nematerminals asingaburitse ma arcs, sparks, kana nzvimbo dzinopisa dzine njodzi panguva yekushanda kwakajairika, zvichiwedzera kuchengetedzeka.

 

Simba Rakakura:Kugona kwayo kunowanzova kwakakura (kubva pamakumi e kVA kusvika kuzviuru zve kVA), inoshandiswa kufambisa michina yakasiyana-siyana ine simba guru pasi pevhu, yakaita semagedhi ekucheka makumbo, magadzirirwo emigwagwa, mabhandi ekufambisa zvinhu, mapombi emvura, uye mafeni ekubatsira.

 

Mavhoriyamu Akasiyana-siyana Ekubuda:Voltage yayo inobuda inosiyana zvichienderana nezvinodiwa nemidziyo yakabatana, izvo zvinogona kuva mazinga emagetsi ari pakati nepakati akadai se660V, 1140V, 3300V, nezvimwewo. Inogonawo kusanganisira 127V winding yekuvhenekesa, asi iri harisi iro basa rayo guru.

 

Dziviriro Yakakwana:Kunze kwekuva isingaputike, inofanirawo kuva nechimiro chakasimba chemuchina, inodzivirira hunyoro hwakanaka, inodzivirira ngura, uye inodzivirira kuvhunduka kuti ikwanise kushanda munzvimbo dzakaoma dzepasi pevhu.

 

Muchidimbu, Transformer yeMigodhi Inodzivirira Kuputika ndiyo "simba rinodzivirira kuputika" rehurongwa hwemagetsi emugodhi; basa rayo guru "kudzivirira kuputika" uye kupa simba remidziyo yakasiyana-siyana.

 

 

Kusiyana Kukuru Pakati Pevaviri

Kuti muenzanise zviri nyore, ndapota tarisai tafura iri pazasi:

Mufananidzo 6.png