Matransformer Akaiswa Pamatanda

Aya ndiwo matangi akaita sedenderedzwa aunoona akabatana nematanda ekushandisa, anowanzo perekedzwa nezvidimbu zvefuse nezvimwe zvinhu zvekushandisa.

  • Kuvaka & Kuisa:Dzakasungirirwa zvakananga padanda riri pakati petambo dzemagetsi dzekutanga (high voltage) nedzechipiri (low voltage). Waya dzemagetsi epamusoro dzinopinda nepamabushingpamusoro, uye waya dzine simba shoma dzinobuda nepadivi pemamiriro ekunze, dzichienda kudivi remagetsi rinodonha rinobatanidza imba.
  • Kushandiswa:Ndivo vanoyerapamusoro Kugoverwa Kwesimba Uchavawana mu:

 

1. Nzvimbo dzekare

2. Nzvimbo dzekumaruwa

3. Mumigwagwa mikuru

4.Kwese kupi uko tambo dzemagetsi dzinofambiswa pamusoro pevhu.

 

  • Zvakanakira:

Mutengo Wakaderera:Zvakachipa kuisa nekugadzirisa sezvo zvisingade kuchera migero yemigero.

Kuwana Zviri Nyore Kwekugadzirisa:Vashandi vemichina vanogona kusvika kwavari nekukurumidza vachishandisa marori emabhaketi.

Nzvimbo Iri Nyore Yekukanganisa:Matambudziko anowanzoonekwa kubva pasi.

 

  • Zvakashata:

Kusangana Nezvinhu Zvine Chekuita:Dzinogona kukuvadzwa nemadutu, mhepo ine simba, miti inodonha, uye kurovera mota nemapango.

Runako:Zvinoonekwa nevakawanda sezvisingafadzi kuona.

Njodzi Yekuchengetedza:Pavanenge vari pamusoro, tsaona kana dutu guru zvinogona kuvawisira pasi, zvichikonzera njodzi.

 

 

MaTransformer Akaiswa Padhi

Aya makabati egirini, esimbi, akakiyiwa ari padanda rekongiri pasi, kazhinji ari muchivako chekumashure, panzvimbo yekupaka mota, kana padivi pechivako chebhizinesi.

 

 

  • Kuvaka & Kuisa:Idzi inhare dzinorema, dzesimbi, dzisingapindiki dzakagadzirirwa kuchengetedza veruzhinji. Tambo dzese dzine simba guru uye dzine simba shoma dzinopinda nekubuda pasi pevhu. Dzakazara nemafuta kana mvura ye dielectric yakachengeteka, isingatsvi zvakanyanya.

 

Kushandiswa:Zvinoshandiswa chete nemasisitimu emagetsi epasi pevhu.Uchavawana mu:

1. Dzimba dzekugara dzemazuva ano

2. Nzvimbo dzemaguta dziri muguta

3. Mapaki ekutengeserana

4. Zvipatara nezvikoro

5. Chero nzvimbo ipi zvayo mitsetse yakavigwa nekuda kwekunaka kana kuvimbika.

 

  • Zvakanakira:

Kuvimbika Kwakawedzerwa:Yakachengetedzwa kubva kumhepo, chando, uye miti inodonha, zvichiita kuti pasave nekudzima kwemvura kwakawanda nekuda kwemamiriro ekunze.

Runako:Hazvinyanyi kuvharika semitsetse nematanda epamusoro, zvichiita kuti nzvimbo yacho ionekwe zvakanaka.

 

Kuchengetedzwa Kweveruzhinji:Kabhineti yesimbi yakakiyiwa uye yakadzika inoita kuti dzisanyanya kubatwa nevanhu netsaona.

 

  • Zvakashata:

 

Mutengo Wakakwira:Zvinodhura zvakanyanya nekuda kwemutengo wekugadzira trenching, conduit, uye transformer pachayo.

 

Kugadzirisa Kunonoka:Kuwana nekugadzirisa zvikanganiso mumitsetse yepasi pevhu kunogona kutora nguva yakawanda uye kunoparadza (zvinoda kuchera).

 

Kusagadzikana kweMafashamo:Inofanira kuiswa munzvimbo dzisingawanzoitiki mafashamo, kana kuti yakagadzirirwa izvi.

 

 

Pfupiso: Musiyano Mukuru

Sarudzo pakati pematransformer akaiswa pamatanda neakagadzirwa papad haisi yekuti imwe ive "iri nani" pane imwe iri mu vacuum. Inyaya yekugadzirwa kwesystem yemagetsi:

 

Matransformer akaiswa pamatanda ndeemitsetse yepamusoro.

Matransformer akaiswa pad anoshandiswa pamitsetse yepasi pevhu.

 

Musiyano mukuru uyu mukushandiswa kwawo unoratidza dhizaini yawo, nzvimbo, mutengo, uye zvakanakira/zvakaipa zvavanounza kune grid yemagetsi.