+86 18068001229 01
Transformer ine 225 kVA 34.5kV ine 3-Phase Pad
Tsananguro yeChigadzirwa
JZP Transformer inodada nekugadzira transformer ine 225 kVA 34.5kV ine 3-phase pad-mounted transformer, yakagadzirirwa masisitimu ekugovera maindasitiri. Yakagadzirwa nemazinga epamusoro-soro, inoita kuti magetsi agare akasimba kune akasiyana mashandisirwo emaindasitiri.
01020304050607
TRANSFORMER YEMAHARA MATATU AKAGADZIRWA
Zvinhu Zvikuru
Kushanda Nesimba & Kugadzira Zvinhu Zvitsva
Mashandisirwo eTransformer e225 kVA
| 225 kVA 34.5kV Transformer Technical Specifications | |
| SIMBA RAKAYERWA | 225 kVA |
| RATINGPRIMARY VOLTAGE | 34500DELTA |
| Vheji Yechipiri | 600GrdY/347 |
| KUWANDA KWEMASHOKO | 60Hz |
| BOKA REVEKTOR | Dyn1 |
| Zvinhu zvinofefetera | Aruminiyamu |
| KURASIKIRWA KWEMUTENGE | ≤2350W |
| Hapana kurasikirwa nemutoro | ≤650W |
| Vheji yeImpedance | 5.75% |
| YAKAKWIRA MUMHEPO | ≤1,500m |
| RUVARA | ANSI 70 Gireyi rakareruka |
| Kurema kwemafuta ekudzivirira kupisa | 1,040 L |
| HUREMU HWOSE | 2,300 kg |
| 225 kVA 34.5kV Transformer Zvishandiso | |
| CHIKAMU CHEKUSIMUDZA | ELSP FUSE |
| Gonhi rine mapapiro | FUSE YEBAYONET |
| BHURAKETI YEKUPAKA | CHINJO CHEKUTAPA |
| Chifukidziro cheTangi | GAUGE YEMAHARA EOIRI |
| LV BUSHING (Maburi mana) | Vharuvhu Yokudzvinyirirwa |
| MUDZIYO WEKUDZORERA KUDZVINYIRIRWA | GAUGE YEKUDZVANYA VACUUM |
| Bhawa remhangura rinogadzira HV | ZVINOTAURA ZVINOTAURA |
| CHIRATIDZO CHETENHERU | Mubato wegonhi |
| TSIME REHV BUSHING (35kV) | TAMBO YEMHARA YEKUGAYA |
| Mubato webhawa remhangura wekukuya | ZVINHU ZVEKUTAURA |
| SWITCH YEKUBVISA MARI PAMUSORO PEZVIVIRI | Mapedhi esimbi yepasi |
| Vharuvhu yekubvisa mvura ine 1" ine 3/8" SAMPLER | Hwindo reIR |
| Vharuvhu yekuzadza yepamusoro ye1" FILTER PAMUSORO PEKUDYA | Bhokisi reChiteshi |
Zvinhu Zvikuru
Hwindo reIR (Hwindo reInfrared)
Transformer yega yega ine mahwindo eIR pamakamuri ane voltage yepamusoro neakaderera, zvichibvumira vashandisi kuita infrared thermal scans vasina kuvhura magonhi. Dhizaini iyi inoita kuti pave nekuongorora kwakachengeteka uye kwakanaka, zvichiita kuti pave nekuona nzvimbo dzinogona kupisa kana matambudziko ekupisa zvakanyanya. Nekuona njodzi dzakadai sekuwanda kwemagetsi, kubatana kusina kusimba, kana kusabatana zvakanaka, IR Window inowedzera kugadzikana uye kuchengetedzeka kwekushanda kwetransformer.
Midziyo Yekudzivirira Yepamusoro
Transformer ye225 kVA ine nzira dzakasiyana-siyana dzekudzivirira kuti ive nechokwadi chekuti mashandiro ayo akachengeteka uye kuti ishande kwenguva yakareba, dzinosanganisira:
Gauge yeKudzvanya Kwevacuum: Inosanganisira ma alarm maviri ekutarisa kudzvanya panguva chaiyo, ichipa yambiro yekutanga yezvinetso zvinogona kuitika.
Mudziyo Wekuderedza Kumanikidzwa: Wakashongedzerwa nekubatana, unotanga chiratidzo chemagetsi kana kumanikidzwa kusina kujairika kwaonekwa, zvichizivisa vanoshanda kuti vatore matanho anodiwa.
Chiratidzo Chemazinga Emafuta: Chine ma alarm maviri anozivisa system yekutarisa kana huwandu hwemafuta husina kunaka, zvichiita kuti vashandi vakwanise kugadzirisa huwandu hwemafuta nekukurumidza uye kuchengetedza kushanda kwakachengeteka.
Chiratidzo chekupisa kwemafuta: Chinosanganisira ma alarm contacts maviri—imwe yezviratidzo zvekunyevera uye imwe yezviratidzo zvekumhanya. Kana kupisa kwemafuta kukadarika 70°C, sisitimu ichaburitsa yambiro; kana ikadarika 105°C, transformer ichadonha yega, uye sisitimu yekutarisa ichatumira chiratidzo kuratidza kutadza.
Dhizaini Inoshanda Nevashandisi & Kutarisa Kunze
MaGauges Akaiswa Kunze uye Drain & Sample Valve: Vashandi vanogona kuyedza mafuta ekudzivirira kupisa uye kuongorora magauges vasina kuzvipinza mumabushing ane voltage yepamusoro uye voltage shoma, zvichiwedzera kuchengetedzeka, kushanda zvakanaka, uye kutevedzera zvinodiwa.
Chidziviriro Chekudzivirira Mudziyo Unodzvinyirira: Chidziviriro ichi chinodzivirira kukuvara kwekunze, kushanda netsaona, uye kukanganiswa nezvinhu zvakatipoteredza, zvichiita kuti mudziyo unodzivisa kumanikidzwa ushande nemazvo uye uderedze njodzi yekubuda kwegasi. Chinodzivirirawo tsvina kuti isapinde mutransformer, zvichichengetedza kuchena uye kugara kwenguva refu.

Kushanda Nesimba & Kugadzira Zvinhu Zvitsva
Transformer ye225 kVA kubva kuJZP Transformer yakagadzirwa ichinyanya kusimbiswa pakuvimbika kwenguva refu uye kuchengetedzeka. Iine mahwindo einfrared, masisitimu ekutarisa akangwara, uye zvidzoreso zvekunze zviri nyore kushandisa, transformer iyi haingogadzirise kushanda zvakanaka chete asiwo inowedzera kuchengetedzeka kwemabasa ekugadzirisa. Izvi zvinobatsira vanoishandisa kuona nekugadzirisa matambudziko anogona kuitika nekukurumidza, zvichideredza nguva yekushanda uye kuve nechokwadi chekuti kugadzirwa kunoramba kuripo.

Mashandisirwo eTransformer e225 kVA
Masisitimu ekugovera magetsi mumaindasitiri
Magetsi emagetsi ekutengeserana uye ekugara
Nzvimbo dzekushandura simba rinodzokororwa uye simba
Nzvimbo dzedata uye zvivakwa zvakakosha
Mitoro yemagetsi inonyanyo shandiswa
JZP Transformer—Kuve nechokwadi cheSimba Rakavimbika reZvaunoda
JZP Transformer yakazvipira kupa mhinduro dzemagetsi dzemhando yepamusoro kuvatengi pasi rese. Kuburikidza netekinoroji yepamusoro uye kudzora mhando kwakasimba, tinovimbisa kuwanikwa kwemagetsi kwakasimba uye kwakavimbika kumapurojekiti akasiyana-siyana emaindasitiri neemabhizinesi. Ingave iri kuisa, kugadzirisa, kana dhizaini yakagadzirwa, tinopa masevhisi ehunyanzvi nerutsigiro.

Bvunza Izvozvi! (or) Bvunza Izvozvi!
Kana muine mibvunzo nezvezvigadzirwa zvedu kana runyorwa rwemitengo, ndapota titumirei email yenyu uye tichakutaurirai mukati memaawa makumi maviri nemana.