JZP Transformer inyanzvi yekugadzira matransformer ane UL listings uye certifications yemazinga emagetsi anosvika 44kV, ichipa mhando dzakasiyana dzematransformer ane UL-certified pad-mounted transformers. Gore rega rega, tinotumira zviuru zvematransformer aya kuUnited States neCanada. Tine hunyanzvi muIEEE/ANSI, CSA, DOE, NEMA, nedzimwe nzira, timu yedu inovimbisa kutevedzera zvinodiwa zvakasiyana-siyana zvemutemo. Kuwedzera kune UL certification, tinewo CSA, MF, CESI certificates, uye mishumo yebvunzo yeSGS yechitatu. Tine ruzivo rwakakura muprojekiti, tinonzwisisa kuti projekiti yega yega ine zvinodiwa zvakasiyana. Ndosaka tichipa matransformer anogadziriswa, zvichibvumira kugadziriswa kwevoltage, kugona, nzira yekubatanidza, uye dhizaini yakakosha kuti ikwane zvaunoda. Iyo 2500 kVA pad mounted transformer inogona kugadziriswa kuti ienderane nezvinodiwa zveprojekiti yako. Bata Daelim Transformer nhasi kuti uwane parameter sheet, drawings, uye quotation ye2500 kVA pad mounted transformer.
01020304050607
| Magadzirirwo eTransformer ye2500 kVA(2.5 MVA) | |||
| Danho | Chikamu chetatu | Std. | ANSI/IEEE Std C57 & DOE 2016 Std |
| Chiyero chesimba | 2000kVA (2.5MVA) | Kugadzirisa | Kudya kwepamberi/kutenderera kwakafa |
| Kuisa | Pad Mount | Kakawanda | 60Hz |
| HV Voltage | 13200/6720V | Chinochinja pombi | Nzvimbo 5 |
| Voltage yeLV | 600/347V | Kugona Kwemvura | 1600L |
| MOTA IPI? | 95 kV | Huremu hwese | 7000kG |
| MOTA YEMOTA YEMOTA | 30 kV | Hapana kurasikirwa nemutoro | 2500W |
| Vectorgroup | MuIn0 | Pamusoro pekurasikirwa nemutoro | 15000W |
| Nzira yekutonhodza | Rambai makadzikama uye muchida | Kusagadzikana | 5.75% |
| Zvinhu Zvinomonera | Aruminiyamu | Ruvara rwependi | Munsell girini |
| Mvura Inoputira | Mafuta emuriwo anoora | Kukwanisa kukwira pa65℃ Tembiricha | 2500 kVA |
| Chimiro chikuru | Chikamu chechitatu chechikamu chechishanu | Mhepo Yakamanikidzwa (Mafeni) | Hapana |

2500 kVA Transformer Zvinhu Zvikuru
Transformer yeZGSL-H-2500/13.2-0.6 ine simba re2500 kVA (2.5 MVA). Transformer iyi ine mapad e2500 kVA ine voltage yekutanga ye13.2/7.62 kV ine Wye connection, high voltage H0 grounding, uye secondary voltage ye600Y/347V Wye ine low voltage H0 grounding.
Transformer yeZGSL-H-2500/13.2-0.6 2500 kVA inogona kushandiswa zvakasiyana-siyana, uye yakakodzera kuiswa mukati nekunze. Matransformer aya ane mvura inodziisa mafuta emuriwo inoora uye inochengetedza tembiricha ichikwira kusvika 65°C. Ane mafuse matatu eELSP nemafuse matatu ebay-o-net ekudzivirira, pamwe chete nemabushing matatu ehigh-voltage, maearbow arresters matatu (HV), uye mabushing mana elow-voltage, rimwe nerimwe riine maburi matanhatu. Nzvimbo yekuisa terminal ine low-voltage yakasimbiswa nePadmount plate. Pamusoro pezvo, transformer ine 2500 kVA pad ine switch ine load-break ine nzvimbo ina uye tap changer ine nzvimbo shanu parutivi rwehigh-voltage.
ZGSL-H-2500/13.2-0.6
ZGSL-H-2500/13.2-0.6 itransformer ine ma pad-phase matatu ye2500 kVA ine UL listing. Transformer ine ma pad ye2500 kVA inotevedzera IEEE C57.12.34 standard uye inoenderana nemitemo yeDOE. Yakagadzirwa nema conductors ealuminium uye yakagadzirirwa se transformer ye loop-feed ye dead-front systems. Nzira yekutonhodza inoshandiswa iKNAN.
ZGS-Z-2500(3050)/44/0.6
ZGS-Z-2500(3050)/44/0.6 itransformer yakasarudzika ye2500 kVA inoiswa pad-front yakagadzirirwa kusangana nezvinodiwa nevatengi vekuCanada neDaelim Transformer. Iyi transformer ye2500 kVA inoiswa pad-pad inoenderana neCSA C227.4 uye CAN/CSA 802.1 standards. Ine voltage yakakwira ye44 kV muDelta configuration uye voltage yakaderera ye600GrdY/347V.
Transformer iyi ine mafuta eRAPO anogona kuora semvura inodzivira kupisa uye yakagadzirirwa kukwira tembiricha ye55°C kana 75°C. Chiyero chayo chekVA i2500 kVA (2.5 MVA) pakukwirira tembiricha ye55°C uye 3050 kVA pakukwirira tembiricha ye75°C.
ZGS-Z-2500(3050)/44/0.6
Chinosiyanisa transformer iyi ye2500 kVA ndechekuti voltage yayo yakaderera yakagadzirirwa kubuda kubva padivi. Uyezve, magauge, tap changer, nameplate, pressure relief valve, uye upper fill valve zvese zviri kunze kwecabin yekumberi. Magauge aya ane contacts uye akabatana mukati meNEMA 4 outdoor control box. Vacuum pressure gauge iri pamusoro pecabin yekumberi. High-voltage bushing i porcelain integrated bushing ine maburi mana, uye HV side ine matatu lightning arresters, imwe neimwe inopa insulation cap yekudzivirira tambo dzeMV. Pamusoro pezvo, maheater anodzivirira condensation akaiswa mucabin yekumberi ine high-voltage kuti ishande zvakanaka.

Transformer yeMVA 3 PH 2.5
ZGSL-Z-2500/44/4.16(2.4) itransformer yakasarudzika ye2.5 MVA ine maphase matatu ine radial pad. Voltage yayo huru i44,000 Delta V, nepo voltage yechipiri iri 4160Y/2400 V. Transformer iyi yakagadzirwa neDYn1 high nelow voltage connection group, uye inoenderana neCSA C227.4 standard. Ine simba rinoshamisa re99.37%, zvichienderana neCAN/CSA-802.3 standard. Kudzivirira kwetransformer pa85°C i5.75%, uye inopa mazinga manomwe e voltage regulation kune high voltage side. Iine insulating oil capability ye2000L uye huremu hwe7500 kg, imuchina wakakura.

Transformer yeMVA 2.5
Zvinoshamisa kuti ine dhizaini apo zvikamu zvemagetsi akakwira neakaderera zvakaiswa parutivi rwekuisa, nechikamu chemagetsi akakwira chine kamuri remhepo rakaiswa zvakanaka rinosvika pachigadziko charo. Kuiswa kwemavharuvhu ezvishandiso nezvimwe zvinhu zvakaiswa zvakanaka pamadziro etangi remafuta ekunze kunoita kuti zvive nyore kupinda uye zvinoita kuti zvive nyore, zvichiratidza dhizaini yakagadzirwa ne transformer.

Transformer Yakaiswa paPad ye2550 kVA
ZGSL-H-2550/34.5/0.415 inomiririra transformer yakasimba ine maphase matatu loop-type pad-mounted, ine simba rinoshamisa re2550 kVA. Inoshanda zvakanaka ne high voltage capacity ye34.5 kV ukuwo ichiburitsa low voltage output ye415Grd/240V. Zvinonyanya kukosha ndezvekuti, high voltage (HV) ne low voltage (LV) windings dzayo dzakagadzirwa nearuminiyamu. Transformer iyi ine efficiency rating ye99.4% uye inoenderana neIEEE Std C57.12.34 standard chaiyo. Uyezve, kuiswa kwayo kwe four-position load-break switch kunosimudzira mashandiro uye matanho ekuchengetedza.

Transformer ye2550 kVA
Transformer ye2550 kVA inoshandisa sisitimu yekutonhodza yeONAN/ONAF, saka, ine mafeni akawanda. Painoshanda nenzira yekutonhodza yeONAN, transformer ine simba re2550 kVA. Zvisinei, nzira yekutonhodza yeONAF inogona kubata simba re3300 kVA. Zvinonyanya kukosha, transformer ine gauge yekupisa kwemafuta ine alarm contacts uye yakabatana nekabhineti kadiki ke304 stainless steel control. Iyi configuration inobvumira kutarisa mamiriro ekushanda kwetransformer kure.
ZGSL-H-2550/34.5/0.415 nhevedzano ine zvikamu zvina, zvakagadzirwa uye zvakagadzirwa zvakanangana nevatengi vekuAmerica, uye yakanyorwa paUL kuti isangane nezvinodiwa zvakasimba zvekuchengetedza uye zvemhando yepamusoro.
ZGSL-H-2550/12.47/0.415
ZGSL-H-2550/12.47/0.415 series ine batch yematransformer e2550 kVA akagadzirwa neJZP Transformer yevatengi vekuAmerica. Matransformer aya ndeemhando yepad-mounted uye ane loop feed configuration. Zvinhu zvakakosha zvematransformer aya zvinosanganisira four-position load-break switch, five-position tap changer, gauges ine no-touch feature, matatu bay-o-net fuses, uye maviri current-limiting fuses.

Transformer ye12.47 kV 2550 kVA
Kudivi rine voltage shoma, kune bracket mumutsara wekutsigira terminal. Mvura inoshandiswa mukudzivirira iASTM II mineral oil, ine simba remagaroni 440. Tangi rakagadzirwa kuti rigone kutsungirira kumanikidzwa kwakanyanya kwetangi kwe10 PSI uye kumanikidzwa kwetangi kwe8 PSI. Kuyerera kwemvura kunochengetwa pa10.0 inches kubva pamusoro pegomba reruoko pa25℃, nekuchinja kwemazinga e0.4 inches pa10℃. Tangi rakagadzirirwa 7 PSI vacuum filling uye rakarongwa kuti rive 2550 kVA kana rawedzerwa simba pa11,847 volts netap changer iri panzvimbo ye124,700-volt yevoltage yechipiri ye415Y/240. Matransformer aya haana mazinga ePCB anoonekwa (asingasviki 2 ppm) panguva yekugadzira, zvichiita kuti pave nekuchengetedzwa kwezvakatipoteredza uye kutevedzera mitemo.

Transformer ye13.2 kV 2550 kVA
Transformer ye2550 kVA itransformer yakagadzirwa zvine UL listing, ichivimbisa kuti inoenderana nekuchengetedzwa kwakasimba uye mwero wemhando. Boka rekubatanidza retransformer iyi ndiDy1·Dd0, inopa nzira mbiri dzakasiyana dzekubatanidza magetsi akaderera:
Pakubatanidza kwe4160V Wye, materminal anosanganisira X1B, X2B, X3B ekubatanidza kwechikamu, X1A, X2A, uye X3A ekubatanidza kusina kwakabatana. Pakubatanidza kwe2400V Delta, materminal ndeaya: C1B kuenda kuX2A, X2B kuenda kuX3A, uye X3B kuenda kuX1A.

Transformer ye24.94 kV 2550 kVA
Matransformer ese e2550 kVA akaiswa pad muchikamu chino akagadzirwa kuti asvike padanho reIEEE C57.12.34, zvichivimbisa mhando yepamusoro uye mashandiro. Ane dhizaini yehuro inoiswa parutivi yekubatanidza kwevoltage yakaderera, zvichibvumira kubatanidzwa zvakanaka neswitchgear. Pamusoro pezvo, switch yekudzora mutoro yematransformer aya e2550 kVA yakagadzirwa neunyanzvi mukati mekamuri ine pressure yakaderera yekabhini repamberi, ichipa nzvimbo ina dzekushanda zvakasiyana-siyana. Tap changer inopa nzvimbo shanu, uye giya rekugadzirisa pressure rakaiswa pa24.94±2×2.5% kuti rive nekutonga kwakaringana. Impedance yematransformer aya pa85°C i5.87%, zvichiita kuti ishande zvakanaka uye zvakagadzikana. Uyezve, maBasic Insulation Levels (BILs) avo ane voltage yepamusoro uye low-voltage akaongororwa pa125kV ne30kV, zvichiteerana, kuti ave nechokwadi chekuti insulation inoshanda zvakanaka.