Matransformer eJZP Single-Phase Pad-Mounted: Mainjiniya Akanyatsonaka Ekuparadzira Simba Rakavimbika​

Matransformer eJZP Single-Phase Pad-Mounted: Mainjiniya Akanyatsonaka Ekuparadzira Simba Rakavimbika​

2025-10-09

Matransformer eJZP ane chikamu chimwe chete akagadzirwa kuti apfuure mwero wepasi rose uku achipa kuchinjika kusingaenzaniswi uye kugara kwenguva refu kune zvinodiwa zvakasiyana-siyana zvekugovera magetsi. Akagadzirwa kuti aenderane uye apfuure ​ANSI, IEEE, DOE, CSA, uye NEMA zviyero, ma transformer aya ane zvinhu zvekuchengetedza zvepamusoro uye kuvaka kwakasimba, zvichiita kuti zvive pachena kuti mashandiro akanaka mumabasa emaindasitiri, ebhizinesi, uye ekugara.

tarisa ruzivo
JZP Power Transformer Icharatidza Zvitsva paElectricity Transformation Canada 2025

JZP Power Transformer Icharatidza Zvitsva paElectricity Transformation Canada 2025

2025-09-30

Semutambi anotungamira muindasitiri yemagetsi ekushandura magetsi, JZP Power Transformer inofara kuzivisa kutora kwayo chikamu muKuchinja Kwemagetsi kuCanada 2025, chiitiko chikuru chakatsaurirwa kuumba ramangwana remagetsi muCanada. Kuratidzwa uku kuchaitika kubva ​Gumiguru 6–8, 2025, paEnercare Center muToronto, Ontario, uye JZP Power Transformer icharatidza mhinduro dzayo dzemazuva ano paBooth 609.

tarisa ruzivo
Ma voltages Akakwira, Apakati, Akaderera, uye Akakwira Zvakanyanya Anoiswa Sei Muma Power Systems?

Ma voltages Akakwira, Apakati, Akaderera, uye Akakwira Zvakanyanya Anoiswa Sei Muma Power Systems?

2025-09-29

Kurongwa kwemazinga emagetsi mumagetsi kwakakosha pakuona kuti simba rinofambiswa zvakanaka, rinoparadzirwa, uye rakachengeteka. Magiredhi emagetsi anosarudza kuti magetsi anotakurwa sei kuburikidza nemagetsi, akaenzana kuti ashande zvakanaka pahunyanzvi uye muhupfumi, uye anogadziriswa kuti ashandiswe zvakasiyana-siyana. Chinyorwa chino chinoongorora zvinodiwa uye zviyero zvinodzora kurongwa uku, tichitarisa pavoltage yakakwira (HV),voltage yepakati (MV)​,voltage yakaderera (LV)​, uyevoltage yakakwira zvakanyanya (UHV)Kurongwa kwemazinga emagetsi mumagetsi kwakakosha pakuona kuti simba rinofambiswa zvakanaka, rinoparadzirwa, uye rakachengeteka. Magiredhi emagetsi anosarudza kuti magetsi anotakurwa sei kuburikidza nemagridi, akaenzana kuti ashande zvakanaka pahunyanzvi uye mune zvemari, uye anogadziriswa kuti ashandiswe zvakasiyana-siyana. Chinyorwa chino chinoongorora zvinodiwa uye zviyero zvinotonga kurongwa uku, tichitarisa pavoltage yakakwira (HV),voltage yepakati (MV)​,voltage yakaderera (LV)​, uyevoltage yakakwira zvakanyanya (UHV).

tarisa ruzivo
JZP Power Transformer: Kusimudzira Remangwana paENLIT Europe 2025

JZP Power Transformer: Kusimudzira Remangwana paENLIT Europe 2025

2025-09-24

Semugadziri anotungamira mukugadzira ma transformer emagetsi epakati nepamagetsi akakwira, JZP Power Transformer inofara kuzivisa kuti tave kutora chikamu mu ENLIT Europe 2025—chiitiko chikuru chekuvandudza simba mukondinendi. Kubva muna Mbudzi 18–20, 2025, ticharatidza mhinduro dzedu dzemazuva ano kuBilbao Exhibition Centre (48100 Bilbao, Bizkaia, Spain). Tishanyirei paBooth 3.F122 kuti muone kuti tiri kuumba sei ramangwana rekutumira nekugovera simba.

tarisa ruzivo
Tibatanei pa2025 3E XPO!

Tibatanei pa2025 3E XPO!

2025-09-24

Mumamiriro ezvinhu anochinja-chinja esimba repasi rose, JZP inomira sesimba guru rinoona nezvema transformer emagetsi ari pakati nepakati nepamusoro—musimboti wekutumira, kugovera, uye kushandisa simba zvinobudirira. Nemakumi emakore ehunyanzvi, tekinoroji yemazuva ano, uye kuzvipira kusingazununguki kune mhando, tinosimudzira maindasitiri, makambani emagetsi, nemapurojekiti pasi rese kuti vawane mhinduro dzesimba dzakavimbika, dzinogara kwenguva refu, uye dzinodhura zvishoma.

 

tarisa ruzivo
Chigadziko cheTransformer chepakati nepamusoro: Gwaro rehunyanzvi

Chigadziko cheTransformer chepakati nepamusoro: Gwaro rehunyanzvi

2025-09-23

Switchgear inoshanda semusana wemagetsi epakati nepakakwirira (MV/HV), ichiita mabasa matatu akakosha kune matransformer:

  • Kugoverwa Kwesimba: Inofambisa magetsi kubva kumatransformer kuenda kumitoro kuburikidza nemafeeder, mabhazi, uye zvishandiso zvekudzivirira.
  • Dziviriro Yemhosva: Inovhiringidza ma currents mukati mema milliseconds (semuenzaniso, 31.5kA–40kA short-circuit break capacity) kudzivirira kukuvara kwemidziyo.
  • Kuzviparadzanisa Nevamwe Vakachengeteka: Inoita kuti pave nekugadziriswa kwakachengeteka kuburikidza nekubatanidza michina uye nzira dzepasi.

Semuenzaniso, sisitimu ye12kV inoda nzvimbo shoma kubva pasi kuenda pasi ye125mm (inodzivirirwa nemhepo) kana 40mm (inodzivirirwa negesi) kudzivirira kutenderera kwemugero.

.

tarisa ruzivo
Kuongororwa kwakadzama kweM&H Voltage Power Electronic Transformer Types, Structural Configurations, uye Key Parameters

Kuongororwa kwakadzama kweM&H Voltage Power Electronic Transformer Types, Structural Configurations, uye Key Parameters

2025-09-22

Kuongororwa Kwakadzama kweM&H Voltage Power Electronic Transformer Types, Structural Configurations, uye Key Parameters

tarisa ruzivo
Ongororo pamusoro peTopology uye Mashandisirwo Ekutonga eMedium-High Voltage Power Electronic Transformers III

Ongororo pamusoro peTopology uye Mashandisirwo Ekutonga eMedium-High Voltage Power Electronic Transformers III

2025-09-18

Nzvimbo ine Neutral Point Clamped (NPC) ine mazinga akawanda inoratidzwa. Kunze kwenzvimbo ine diode-clamped NPC, nzvimbo dzine NPC dzinosanganisirawo mhando ye flying capacitor uye mhando ine hybrid clamped, pakati pezvimwe. Zvisinei, nekuda kwehuwandu hukuru hwe capacitor, nzvimbo dzine NPC dzichiri kushandisa zvakanyanya passive kana active switching devices passive kana active switching devices. Tichitora nzvimbo ine diode-clamped multilevel semuenzaniso, mune three-phase rectifier stage topology, phase leg yega yega ine cascaded switching transistors uye clamping diodes, dzakabatana zvakafanana ne single high-voltage DC bus. Mabhuku akakurudzira single-phase PET topology ine rectifier stage ichishandisa four-level diode-clamped circuit. Single high-voltage DC bus inoteverwa ne input-series-output-parallel DABs, sezvakaratidzwa. Iyi nzvimbo inogona kuwedzerwa kuita three-phase structure, uye huwandu hwe voltage levels hunogona kuchinjwa zvichienderana ne device standing voltage levels uye high-voltage side voltage level. Kufanana neMMC topology, NPC topology inogonawo kushandiswa padanho rekupatsanura, ichibatanidza bhazi reDC rine voltage yakakwira netransformer yekupatsanura, sezvakaratidzwa. Mabhuku akashandisa converter yeNPC ine diode-clamped yemazinga matatu kudivi revoltage reLLC resonant converter, vachiisimbisa paprototype ye166kW/2kV~400V. Mabhuku akashandisa circuit yeNPC ine diode-clamped yemazinga matatu kuDAB ine phase nhatu, zvichiita kuti DAB voltage yakanakira uye hunhu hwemazuva ano huve hwakakodzera.

tarisa ruzivo
Ongororo pamusoro peTopology uye Mashandisirwo Ekutonga eMedium-High Voltage Power Electronic Transformers II

Ongororo pamusoro peTopology uye Mashandisirwo Ekutonga eMedium-High Voltage Power Electronic Transformers II

2025-09-18

Matoporiji ePET anosiyana zvakanyanya. Zvichienderana nehuwandu hwematanho ekushandura simba, anogona kuiswa muzvikamu zveimwe-nhanho, zviviri-nhanho, uye zvitatu-nhanho [7]. Maumbirwo ezvikamu zviviri anosanganisira ayo ane mabhazi eDC ane voltage yakakwira uye yakaderera, sezvakaratidzwa muMufananidzo 1.

tarisa ruzivo
Ongororo pamusoro peTopology uye Mashandisirwo Ekutonga eMedium-High Voltage Power Electronic Transformers I

Ongororo pamusoro peTopology uye Mashandisirwo Ekutonga eMedium-High Voltage Power Electronic Transformers I

2025-09-16

Nekukurudzirwa kwepfungwa yeinternet yesimba uye kushandiswa kwakapararira kwetekinoroji ine chekuita negrid yakangwara, huwandu hwesimba rinogona kudzokororwa senge simba remhepo nemagetsi aripo muhurongwa hwesimba huripo huchawedzera zvakanyanya. Izvi zvinoratidza kuti magrid emagetsi emangwana achava akangwara uye anochinjika. Muinternet yesimba, sezvo huwandu hwevashandisi vakagoverwa uye zviwanikwa zvesimba zvichikwira, kutapurirana kwemagetsi kunoda kugona kudzorwa zvakanyanya. Munetwork dzemagetsi dzakangwara, grid inofanira kuchengetedza simba rakasimba uye remhando yepamusoro uku ichibatanidza huwandu hwakawanda hwesimba rinogona kudzokororwa rakagoverwa uye mamiriro ekutarisa/kutarisira mashandiro egrid. Izvi zvinodiwa zvinoisa zvinodiwa zvakanyanya pahungwaru hwemidziyo yemagetsi, nepo ma transformer emagetsi echinyakare anotarisana nemiganho yekushanda.

tarisa ruzivo