Mhinduro dzeMagetsi Emagetsi Akagadzirwa≤2500 kVA
Zviyero zvechigadzirwa
| Rudzi | Kugona | Mwero weVoltage | Kutonhodza | Kushandiswa |
| Transformer yekugovera | 1,600 kVA | 11 kV / 400 V | VECHIDIKI | Dzimba dzekugara/dzemaindasitiri |
| Simba Rinoshandura | 500 MVA | 220 kV / 33 kV | OFAF | Nzvimbo yekutumira mashoko munharaunda |
| Chinjara cheUHVDC | ±400 kV / 500 MVA | HVDC ±800 kV | Oiri yakamanikidzwa | Magridhi epakati pemakondinendi |
| Chinoshandura Chinogadzirisa | 20 MVA | 33 kV / 1.8 kV × 6-pulse | Rudzi rwakaoma, rwakatonhorerwa nemhepo | Kugadziriswa kwemagetsi ealuminium |







tsananguro yechigadzirwa
1. Kugona Kwakayerwa (MVA/kVA)
Tsanangudzo: Simba guru rinobuda nguva dzose rinogona kuburitswa netransformer.
Mhando Dzakajairika:
MaTransformer Ekuparadzira: ≤2,500 kVA (semuenzaniso, kugoverwa kwenzvimbo dzekugara kana dzemaindasitiri).
Masimba Anoshandura: Zviuru zve kVA kune maGVA akati wandei (semuenzaniso, nzvimbo dzekutumira magetsi).
MaTransformer eHigh Voltage (UHV): Ekubatanidza grid kana kushandiswa mumaindasitiri, matransformer eHVDC anosvika ±800 kV.
2. Kuyera Voltage
MaVhoriyamu Ekupinda/Kubuda:
High Voltage (HV): Kazhinji 33 kV kusvika ±1,100 kV (semuenzaniso, magedhi ekutumira).
Voteji Yepakati (MV): Yakajairika 11 kV, 22 kV, 33 kV.
Voteji Yakaderera (LV): Kazhinji 400 V kana 6.6 kV (inogoverwa kune vashandisi).
Zvikumbiro Zvakakosha:
MaRectifier Transformers: Kune simbi/makemikari, mavoltage anosvika 30 kV+.
MaTransformer eTraction Traction: Akagadzirirwa simba remotokari, semuenzaniso, 27.5 kV kana 1×25 kV.
3. Kuwanda
Standard: 50 Hz (China/Europe) kana 60 Hz (North America).
Mafambiro Akakosha: 400 Hz yekushandiswa kwendege/mugungwa.
4. Sisitimu Yekutonhodza
Akanyudzwa muOiri:
ONAN (Oiri Yemhepo Yechisikigo): Kutonhodza kwemhepo inotonhorera.
ONAF (Oiri Yechisikigo Inomanikidzwa Nemhepo): Kutonhodza kwemhepo kunomanikidzwa kuti kushande zvakanaka.
Rudzi Rwakaoma: Rwakatonhodzwa nemhepo, rwakakodzera nzvimbo dziri mukati/dzinotsvedza nemoto (semuenzaniso, nzvimbo dzedata).
Gas-Insulated (GIS): SF6 gas insulation, dhizaini diki ye substations dzine density yakakura.
5. Rudzi rwekudzivirira
Mafuta Akanyudzwa: Mafuta emineral kana ester (asingakuvadzi nharaunda).
Rudzi Rwakaoma: Epoxy resin casting kana Nomex paper insulation (inodzivirira moto/kuputika).
Gas-Insulated: SF6 kana magasi akasanganiswa (zviteshi zvemagetsi zvine simba rakawanda).
6. Kushanda zvakanaka
Maitiro Akajairika:
MaTransformer Ekuparadzira: ≥98% (kurasikirwa kwakaderera kwemutoro uye kurasikirwa nemutoro).
MaPower Transformers: ≥99% (mamodheru emagetsi akakwira zvakanyanya anobudirira zvakanyanya).
Mitemo: Tevedzera IEC 61620 kana IEEE C57.12 (semuenzaniso, zvinodiwa neEU Ecodesign).
7. Boka reKubatanidza
Musiyano wePhase: Unozivikanwa seDyn11, Yd11, zvichiratidza hukama hwephase pakati pemawindings ekugadzirisa harmonics uye ma short-circuit currents.
8. Impedance Voltage
Tsanangudzo: Kudzikira kwepercentage voltage panguva yekuedzwa kwe short-circuit, zvichiratidza kugona kwe short-circuit kumira.
Maitiro Akajairika: 4–10% (matransformer emagetsi), ≤4% (matransformer ekuparadzira).
9. Kukwira kweTembiricha
Miganhu: Matransformer anonyudzwa mumafuta anowanzo bvumira kukwira kwetembiricha ye ≤55 K (mafuta epamusoro pa40°C).
Kujairana Nezvakatipoteredza: Nzvimbo dzerenje dzinoda kushatirwa kwakanyanya.
10. Kuongororwa kweDziviriro
Makodhi eIP:
IP23: Inopfapfaidzwa isina guruva, isingapindi mvura.
IP66/IP68: Yakavharwa zvizere kubva muguruva/mvura (kushandiswa kwemvura/kunze kwegungwa).
Nzvimbo Dzakakosha: Kudzivirira ngura yemunyu inoshandiswa pakushandiswa pamhenderekedzo yegungwa/pasi pegungwa.
11. Mhando Dzakasarudzika
MaRectifier Transformers: Magadzirirwo emapulse akawanda (semuenzaniso, 12/24-pulse) kuderedza maharmonics.
MaTransformer Anochinja Tap: Anochinja Tap On-load (OLTC) ekugadzirisa voltage.
MaTransformer Akakosha:
Matransformer eFurnace emagetsi: Akagadzirirwa kushandiswa kwenguva pfupi (semuenzaniso, kunyungudutsa simbi).
MaZigzag Transformers: Masisitimu ekudzika pasi asina kwaakarerekera ekudzvinyirira harmonic.
Rudzi Kushandiswa kweKukwanisa Kutonhodza Voltage Level
Transformer yekugovera 1,600 kVA 11 kV / 400 V ONAN Dzimba dzekugara/dzemaindasitiri
Simba reTransformer 500 MVA 220 kV / 33 kV OFAF Nzvimbo yekutumira magiya yedunhu
Chinoshandura UHVDC ±400 kV / 500 MVA ±800 kV HVDC Mafuta anomanikidzwa emagetsi epakati pemakontinenti
Rectifier Transformer 20 MVA 33 kV / 1.8 kV × 6-pulse Aluminium electrolysis yemhando yakaoma, inotonhodzwa nemhepo



Sei uchifanira kusarudza isu?
JIEZOU POWER, nyanzvi yekugadzira, kugadzira uye kuisa mhinduro yemagetsi pasi rose, yakavambwa mugore ra1989, ine nzvimbo inosvika 200,000 square metres.
JIEZOU POWER, inonyanya kutarisira mapurojekiti emagetsi, 500KV EPC, 230KV hydroelectric power plant, 115KV power substation, nezvimwewo.
Fekitori yeJIEZOU POWER inogona kugadzira transformer yemhando yemafuta neyemhando yakaoma, ine simba repamusoro re500KV 480MVA power transformer, GIS, switchgear, substation, zvichibva paANSI/IEEE/DOE2016/CSA/IEC60076 standard.
JIEZOU POWER inowana ISO9001, ISO14001, ISO45001, UL, CUL, CSA certificate, SGS, TUV, INTERTEK, TYPE TEST REPORT zvakatevedzana. Kusvika gore ra2023, makambani nemafekitori epasi rose ari kugoverwa muUnited States, Canada, Dubai, Dominican Republic, Philippines, mafekitori nemafekitori ebazi reChina ari muguta reBengBu, guta reFengYang, guta reHaiAn, guta reTaiZhou, guta reSuZhou, guta reShenYang, guta reFoShan.
Tichitarisa ramangwana, chinangwa chaJIEZOU POWER ndechekuva mupi wemhinduro dzemagetsi anonyanya kuvimbwa naye, kugadzirisa matambudziko ekugadzirisa masimba emagetsi anonyanya kukurumidza pasi rose, kukurumidzisa shanduko yepasi kuenda kusimba rinodzokororwa. Kuti munhu wese ave nehupenyu husina kabhoni yakawanda uye hwakajeka. Kuti izvi zviitike, tichaita zvese zvatinogona kuti tishande nesimba.



Bvunza Izvozvi! (or) Bvunza Izvozvi!
Kana muine mibvunzo nezvezvigadzirwa zvedu kana runyorwa rwemitengo, ndapota titumirei email yenyu uye tichakutaurirai mukati memaawa makumi maviri nemana.