Leave Your Message

MaTransformer emafuta e220kVA Anoshanda Zvakanyanya Ekushandisa Zvinhu Zvine Basa Rakawanda

​220kVA Oil Immersed Transformer​ chishandiso chemagetsi chakavimbika uye chinoshanda zvakanaka chakagadzirirwa kushandiswa mumaindasitiri, mabhizinesi, uye zvivakwa. Chinoshandisa mafuta emineral kana mafuta anochengetedza nharaunda kuti atonhore, zvichiita kuti magetsi achinjike (semuenzaniso, 10kV kusvika 0.4kV). Yakavakwa nezvinhu zvakasimba uye tekinoroji yepamusoro, inopa hupenyu hurefu, kuchengetedza kwakaderera, uye kugona kuchinjika munzvimbo dzakaoma.

    Zvimiro zveMaumbirwo

    Core​
    Mitsetse yesimbi yesilicon inopinzwa zvakanaka inotonhorera ine insulation yezvikamu kuti ideredze kurasikirwa kwemvura inonaya.
    Dhizaini yemakumbo mashanu ine zvikamu zvitatu yekuderedza zero-sequence impedance uye kudzvinyirira harmonics.
    Mawindings​
    Kuvharira Kwemagetsi Akawanda: Copper foil ronda ine Nomex paper interlayer insulation.
    Kutenderedza Mavhiri Mashoma: Chimiro chesilinda chine mativi akawanda chinobatsira kudzivirira mavhiri mapfupi.
    Tangi uye Kutonhodza​
    Dhizaini yeONAN ine mafuta echisikigo uye isina mafeni ekunze, yakakodzera kuiswa panze.
    Mafin eradiator ane corrugated akabatanidzwa mutangi kuti abvise kupisa zvakanaka.
    Sisitimu yekudzivirira
    Mafuta emaminerari (kana mafuta ester asingakuvadzi nharaunda) anopa kudzivirira kupisa, kutonhora, uye kudzima kwearc.
    Chikamu chekubuditsa mvura ≤50pC (IEC 60076 inoenderana nezvinodiwa).
    Transformer Inonyudzwa neOiri yeCooper Inoyerera Frequency Yakakwira 10001Transformer Inonyudzwa neOiri yeCooper Inoyerera Frequency Yakakwira 10002Transformer Inonyudzwa neOiri yeCooper Inoyerera Frequency Yakakwira 10003
    Core​
    • MaTransformer e220kVA Oiri Anoshanda Zvakanyanya (1)
    • MaTransformer e220kVA Oiri Anoshanda Zvakanyanya (2)
    • MaTransformer e220kVA Anoshanda Zvakanyanya Ekushandisa Zvinhu Zvine Basa Rakawanda (3)
    • MaTransformer e220kVA Anoshanda Zvakanyanya Ekushandisa Zvinhu Zvine Basa Rakawanda (4)
    • MaTransformer e220kVA Anoshanda Zvakanyanya (5)
    • MaTransformer e220kVA Anoshanda Zvakanyanya Ekushandisa Zvinhu Zvine Basa Rakawanda (6)
    Transformer Inonyudzwa neOiri yeCooper01

    Mashandisirwo

    Kugoverwa Kwesimba reMaindasitiri​
    Kugoverwa kwemagetsi ari pakati nepakati (10kV kusvika 0.4kV) mumafekitori, migodhi, uye mafekitori esimbi.
    Inotsigira kuwandisa kwenguva pfupi (semuenzaniso, maovheni emagetsi, mainjiniya matsva).
    Zvivako zveMabhizinesi​
    Kugoverwa kwemagetsi kumashopu makuru, mahofisi, nemahotera.
    Zvivakwa​
    Zviteshi zvezvitima, nhandare dzendege, uye nzvimbo dzekuchenesa mvura yakasviba.
    Nzvimbo dziri kure
    Inoshanda zvakanaka munzvimbo dzine hunyoro hwakawanda, dzine guruva, kana kuti tembiricha inochinja-chinja.

    Zvakanakira Zvikuru

    Kuvimbika Kwakanyanya​
    Tangi rakavharwa zvizere rinodzivirira oiri kusvibiswa uye kusvibiswa.
    Kukwanisa kwakasimba kutsungirira mafambiro mapfupi (GB/T 1094.5 inoenderana).
    Kugadziriswa Kushoma​
    Dhizaini isina kugadziriswa ine kutarisisa huwandu hwemafuta uye tembiricha panguva chaiyo.
    Inodhura Zvishoma​
    Mari shoma yekutanga uye kurasikirwa nesimba kushoma pakushanda.
    Sarudzo Dzisingakuvadzi Kuchengetedza Ruzivo​
    Inowanikwa nemafuta e-ester anoora (semuenzaniso, FR3) kuti itevedzere RoHS.

    Nhungamiro dzeSarudzo​

    Chikwata chimwe nechimwe chinoedzwa zvakasimba, kusanganisira:
    Kudzivirira insulation uye bvunzo dzemagetsi ekupinza simba.
    Kuyerwa kwekurasikirwa nemutoro uye kuyera kurasikirwa nemutoro pasina mutoro.
    Kuongororwa kwe "short-circuit" kunodzivirira kutenderera.
    Yakatenderwa neISO 9001, ISO 14001, uye KEMA kuti inotevedzera mitemo yepasi rose.

    Nhungamiro dzeSarudzo

    Hunhu hweMutoro​
    Simbisa rudzi rwemutoro (rwakagadzikana kana kuti rwunochinja-chinja).
    Ongorora zvinodiwa zvekushandisa zvakanyanya kwenguva pfupi (semuenzaniso, maovheni emagetsi).
    Mamiriro Ezvakatipoteredza​
    Kureba ≤1,000 metres (kureba kunodiwa pamusoro peizvi).
    Tembiricha yekunze: -25℃ kusvika +45℃ (kutonhorera kwakawedzerwa munzvimbo dzinopisa).
    Kutevedzera mitemo​
    Inosangana neGB 1094 (China), IEC 60076 (yepasi rose), uye zvitupa zvinoenderana neindasitiri (semuenzaniso, ATEX yemhepo inoputika).

    Kuiswa uye Kugadziriswa​

    Zvinodiwa pakuisa​
    Nheyo yakatsetseka ine nzvimbo yakasununguka ye ≥1m kumativi ese kuti iparadze kupisa.
    Kudzivirira pasi ≤4Ω; dhizaini yakasiyana yekudzivirira mheni.
    Kugadzirisa Kwenguva Dzose​
    Tarisa huwandu hwemafuta, ruvara, uye kudonha kwemvura mwedzi mitanhatu yega yega.
    Edza kudzivirira kupisa kwemhepo gore rega rega uchishandisa megohmmeter ye2,500V.
    Kugadzirisa Matambudziko​
    Kupisa zvakanyanya: Ongorora kuvharika kweradiator kana kuti zvinhu zvisina kujairika.
    Kuongorora Oiri Chromatography: Ona zviratidzo zvekutanga zvekubuda kwemukati kana kuora kwekudzivirira kwemukati.
    Transformer Inonyudzwa neOiri yeCooper02Transformer Inonyudzwa neOiri yeCooper03Transformer Inonyudzwa neOiri yeCooper04Transformer Inonyudzwa neOiri yeCooper05

    Sei uchifanira kusarudza isu?

    JIEZOU POWER, nyanzvi yekugadzira, kugadzira uye kuisa mhinduro yemagetsi pasi rose, yakavambwa mugore ra1989, ine nzvimbo inosvika 200,000 square metres.
    JIEZOU POWER, inonyanya kutarisira mapurojekiti emagetsi, 500KV EPC, 230KV hydroelectric power plant, 115KV power substation, nezvimwewo.
    Fekitori yeJIEZOU POWER inogona kugadzira transformer yemhando yemafuta neyemhando yakaoma, ine simba repamusoro re500KV 480MVA power transformer, GIS, switchgear, substation, zvichibva paANSI/IEEE/DOE2016/CSA/IEC60076 standard.
    JIEZOU POWER inowana ISO9001, ISO14001, ISO45001, UL, CUL, CSA certificate, SGS, TUV, INTERTEK, TYPE TEST REPORT zvakatevedzana. Kusvika gore ra2023, makambani nemafekitori epasi rose ari kugoverwa muUnited States, Canada, Dubai, Dominican Republic, Philippines, mafekitori nemafekitori ebazi reChina ari muguta reBengBu, guta reFengYang, guta reHaiAn, guta reTaiZhou, guta reSuZhou, guta reShenYang, guta reFoShan.
    Tichitarisa ramangwana, chinangwa chaJIEZOU POWER ndechekuva mupi wemhinduro dzemagetsi anonyanya kuvimbwa naye, kugadzirisa matambudziko ekugadzirisa masimba emagetsi anonyanya kukurumidza pasi rose, kukurumidzisa shanduko yepasi kuenda kusimba rinodzokororwa. Kuti munhu wese ave nehupenyu husina kabhoni yakawanda uye hwakajeka. Kuti izvi zviitike, tichaita zvese zvatinogona kuti tishande nesimba.
    Transformer Inonyudzwa neOiri yeCooper06Transformer Inonyudzwa neOiri yeCooper07Transformer Inonyudzwa neOiri yeCooper08Transformer Inonyudzwa neOiri yeCooper09

    Bvunza Izvozvi! (or) Bvunza Izvozvi!

    Kana muine mibvunzo nezvezvigadzirwa zvedu kana runyorwa rwemitengo, ndapota titumirei email yenyu uye tichakutaurirai mukati memaawa makumi maviri nemana.

    Leave Your Message